MAINTENANCE
WARNING
To reduce the risk of serious bodily injury, including
splashing in the eyes or on the skin, or injury from
moving parts, ALWAYS shut off the air supply and
relieve all air and fluid pressure in the system be-
fore removing or servicing the air regulator.
The regulator does not have to be removed from the air
line to clean it. Remove the two No. 10–32 screws on the
bottom of the regulator, then pull out the inner valve
assembly.
Wash the inner valve assembly with solvent. Be careful
not to damage the diaphragm and valve facings.
CAUTION
Do not use acetone, carbon tetrachloride, trichlo-
rethylene or similar solvents to clean the regula-
tor. These solvents could damage regulator
parts.
Be sure the spring housing vent hole is not clogged. Keep
the vent hole clear as a slight flow of air through this hole
is necessary for the regulator to operate properly.
Lubricate the adjusting screw with petroleum jelly.
TROUBLESHOOTING
PROBLEM WHAT TO DO
High bleed rate Check relief seat & relief valve for damage
or foreign matter
Leakage Check for diaphragm damage
Valve chatter Lubricate seal rings
Air pressure
gauge reading
slowly changing
Make sure shipping plug in spring cap
vent hole is removed
6–1/2
4–3/8
2–3/4
1
1–7/8
3
1/4 npt INLET
& OUTLET
VENT
1/4 npt GAGE PORT
MOUNTING HOLES
1/4-20 x 0.5 deep
DIMENSIONAL DRAWING
NOTE: All measurements
in inches.
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441
308024 12–88 Revised 2/09
ACCESSORIES
AIR PRESSURE GAUGE 185350
0–15 psi (1–103 KPa) Range
1/4 npt(m) bottom inlet
ADAPTER UNION 110232
1/4–18 npt(m x f) , 45 swivel
ADAPTER 159842
1/4 npt(m) x 1/2 npt(f)
ADAPTER 110249
1/4–18 npt(m), 90 elbow
185350
110232
159842
110249
2–1/4
1-7/16
2–3/16
OUTLET
INLET
Przeglądanie stron 1