Graco 332455F Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Nie Graco 332455F. Graco 332455F User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
Instructions-Parts
Color Change K
its
332455F
EN
To add optional color change function to ProMix® PD2K Electronic Proportioners. Kits include low or
high pressure color/catalyst change valves and a Non-IS or IS control module.
For professional use only.
Important Safety Instructions
Read all warnings and instructions in this manual and in your PD2K
proportioner manual. Save these instructions.
See page 4
for model part
numbers a
nd approvals
informat
ion.
PROVEN QUALITY. LEADING TECHNOLOGY.
Przeglądanie stron 0
1 2 3 4 5 6 ... 73 74

Podsumowanie treści

Strona 1 - Color Change K

Instructions-PartsColor Change Kits332455FENTo add optional color change function to ProMix® PD2K Electronic Proportioners. Kits include low orhigh pr

Strona 2 - Contents

Important Isocyanate (ISO) InformationImportant Isocyanate (ISO) InformationIsocyanates (ISO) are catalysts used in twocomponent materials.Isocyanate

Strona 3 - Related Manuals

Important Isocyanate (ISO) InformationChanging MaterialsNOTICEChanging the material types used in yourequipment requires special attention to avoidequ

Strona 4 - Non-Intrinsically Safe Kits

Setup the ModulesSetup the ModulesSetup Non-IS Control ModulesNOTE: The PD2K System can use up to four pumpsand six color change modules in the non-ha

Strona 5 - 332455F 5

Setup the ModulesConfigure each module according to its designatednumber, as follows:NOTICETo avoid damaging the circuit boards, wear PartNo. 112190 gr

Strona 6 - Intrinsicall

Setup the ModulesNon-IS Control Module 1Inlet ManifoldOutlet ManifoldSolenoidValveSolenoidValve1Solvent1Dump2Color 12Color 13Color 23Color 24Color 34C

Strona 7 - Warnings

Setup the ModulesSetup IS Control ModulesNOTE: Two color change control modules may beinstalled in the hazardous area. The modules arelabeled 7 or 8.

Strona 8 - 8 332455F

Setup the ModulesIS Control Module 7SolenoidValveSolenoidValve1ColorSolvent1CatalystSolvent2Color 12Catalyst 13Color 23Catalyst 24Color 34Catalyst 35C

Strona 9 - 332455F 9

InstallationInstallation• To avoid electric shock, turn off power atthe main circuit breaker before opening theenclosure.• All electrical wiring must

Strona 10 - Important Iso

InstallationNon-Hazardous LocationNOTE: Non-IS color change control modules providecontrol for the pump’s inlet and outlet color/catalystchange valves

Strona 11 - Changing Mate

InstallationNotes332455F 19

Strona 12 - Setup the Modu

ContentsRelated Manuals ... 3Models... 4Non-I

Strona 13 - 332455F 13

InstallationHazardous LocationNOTE: IS colorchange control modules providecontrol for color/catalyst change valves located in thehazardous location. A

Strona 14

Installation5. Mount a second color control module asdescribed in Mounting the Color ChangeControl Module, page 17. Connect the suppliedhazardous loca

Strona 15 - Setup IS Contr

InstallationNotes22332455F

Strona 16 - 16 332455F

InstallationInstall the Back Pressure Regulator(High Pressure Systems Only)NOTE: The back pressure regulator is required onhigh pressure systems to pr

Strona 17 - Installation

InstallationConnect the Fluid LinesConnect Non-Circulating Fluid LinesNOTE: There can be only one solvent valve (S) andone dump valve (D) per pump.NOT

Strona 18 - Non-Hazardous Location

Installation6. Connect a dedicated gun supply line for eachcolor to the corresponding color valve fitting (C1,C2, etc.) on the outlet color valve stack

Strona 19 - 332455F 19

InstallationConnect Circulating Fluid LinesCirculation valves enable constant circulation of acolor when that color is not being sprayed:•Whenacolorva

Strona 20 - Hazardous Location

InstallationFluid Flow Schematic Diagram in Circulating Mode (Pump Not Shown for Clarity)KEYAColor supplyB Inlet color stackC Outlet color stackDY fitt

Strona 21 - Valve Manifolds

InstallationInstall an Expansion KitExpansion Kits are available to addvalves or manifolds to your system. SeeExpansion Kits, page 64 for available ki

Strona 22

InstallationInstall an Expansion Kit (Low PressureValve Manifold Shown)Non-CirculatingCirculating332455F 29

Strona 23 - Connect the Valve Air Lines

Related ManualsRelated ManualsManual No. Description3A2800 PD2K Proportioner Repair-PartsManual, ManualSystems332457 PD2K Proportioner InstallationMan

Strona 24 - Connect the Fl

TroubleshootingTroubleshootingNOTE: Check all possible remedies before disassembling the system.Color Change Solenoid ValvesNOTE: Refer to Electrical

Strona 25 - 332455F 25

TroubleshootingCause Solution4. Control board or cablefailure.Ifthereisnovoltage across the pins on the board or it is less than 9 Vdc, checkLEDs D8,

Strona 26 - 26 332455F

TroubleshootingColor Change BoardNOTICETo avoid damaging the circuit boards, wear PartNo. 112190 grounding strap on your wrist andground appropriately

Strona 27

TroubleshootingColor Change Board DiagnosticsComponent orIndicatorDescription DiagnosisD8LED (green) Blinks (heartbeat) during normal operation.D9LED

Strona 28 - Install an Expansion Kit

Electrical SchematicsElectrical SchematicsNOTE: The electrical schematic illustrates all possiblewiring expansions in a ProMix PD2K system. Somecompon

Strona 29 - Valve Manifold Shown)

Electrical Schematics+24VDCCOM+24VDCCOMPWR (RED)SIG (WHITE)COM (BLACK)SHIELD/GRNMANIFOLDGROUND BARINLET TRANSDUCERPUMP 1(16P289 OR 16P290)OUTLET TRANS

Strona 30 - Troubleshooting

Electrical SchematicsGUN TRIGGER INPUTSGFB PRESSURE SWITCH (121323)SOLVENT FLOW SWITCH (120278)1234512345LIGHTTOWER(15X472)ADVANCEDDISPLAY MODULE(24E4

Strona 31 - 332455F 31

Electrical SchematicsCOLOR CHANGEMODULE 1(COLORS1 THRU 8)123456MANIFOLD123456123456J8J15J14J9J10J161234512345COLORCHANGEMODULE 2(COLORS9 THRU 16)J8J15

Strona 32 - Color Change B

Electrical SchematicsCATALYSTCHANGEMODULE 5(CATALYST1 THRU 2)123456MANIFOLD123456123456J8J15J14J9J10J161234512345CATALYSTCHANGEMODULE 6(CATALYST3 THRU

Strona 33 - 332455F 33

Electrical SchematicsFROM CAN IS BOARD (24M485) ON PAGE 2BOOTH CONTROL(24M731)COLORCHANGEMODULE 7(COLORS33 THRU 40)J8J15J14J9J10J161234512345COLORCHAN

Strona 34 - Electrical Sc

ModelsModelsNon-Intrinsically Safe KitsSee the module identification label for product part number, maximum air working pressure, and approvalinformati

Strona 35 - (24N913)

Electrical SchematicsOptional Cables and ModulesNOTE: Thetotallengthofallcableusedinthesystemmustnotexceed150ft(45m). See theElectrical Schematics, pa

Strona 36

RepairRepair• To avoid electric shock, turn off power at themain circuit breaker before opening the controlmodule.• All electrical wiring must be done

Strona 37 - 332455F 37

RepairReplace a Solenoid1. Remove electrical power from the system.2. Remove air supply pressure from the system.3. Remove the color change module cov

Strona 38 - 38 332455F

RepairReplace the Color Change BoardNOTICETo avoid damaging the circuit boards, wear PartNo. 112190 grounding strap on your wrist andground appropriat

Strona 39 - 332455F 39

PartsPartsNon-IS SystemShownDetail of Back Pressure Regulator (High Pressure Outlet Stack only)44332455F

Strona 40 - Optional Cabl

PartsNon-IS Color Change KitsRef.No.PartNo.DescriptionQty101 24U237BRACKET, mounting1102◆KIT, manifold, valve2103 100157SCREW, cap, hex head;1/4–20 x

Strona 41 - Replace a Color Valve

PartsHigh Pressure Non-IS KitsKit No. Kit DescriptionStandard ValveManifold Kits(102) [seeHigh PressureValve ManifoldKits, page 55 forall availablekit

Strona 42 - Replace the Co

PartsIS Color ChangeKitsRef.No.PartNo.DescriptionQty101 24U237BRACKET, mounting1102◆KIT, manifold, valve; mustbe ordered separately. SeeValve Manifold

Strona 43

PartsHigh Pressure IS KitsKit No. Kit DescriptionStandard ValveManifold Kits(102) [seeHigh PressureValve ManifoldKits, page 55 forall availablekits]Co

Strona 44 - Non-IS System

PartsValve ManifoldsLow Pressure Valve Manifold KitsNon-Circulating Valve Manifold KitsKit No.SeriesKit Description24T457 A 2 valves24T458 A 3 valves2

Strona 45 - Non-IS Color C

ModelsKit No.SeriesKit DescriptionMaximum Air Working Pressure(Control Module)Maximum Fluid WorkingPressure (Valves)High Pressure Non-Circulating Colo

Strona 46 - High Pressure Non-IS Kits

PartsValve Manifold Kit PartsNon-CirculatingKitsCirculating Kits50 332455F

Strona 47 - IS Color Chang

PartsRef.No.PartNo.DescriptionQty116P259MANIFOLD2111450O-RING; chemically resistant24T441VALVE, for non-circulatingkits; includes item 2324T442VALVE,

Strona 48 - High Pressure IS Kits

PartsReference NumbersKit No.12345678 1012 131415161718 1924T4751020 20 0 20 11 1 1 3 21 21 20 15 0 1 20 024T4761122 21 1 22 12 1 1 3 22 22 21 15 3 1

Strona 49 - Valve Manifol

PartsLow Pressure Circulating Valve Manifold Kit Part QuantitiesReference NumbersKit No.12345678 1012131415 161718 192224T487121022 11355203100124T488

Strona 50 - 50 332455F

PartsNotes54 332455F

Strona 51 - 332455F 51

PartsHigh Pressure Valve Manifold KitsNon-Circulating Valve Manifold KitsKit No.SeriesKit Description24T647 A 2 valves24T648 A 3 valves24T649 A 4 valv

Strona 52 - 52 332455F

PartsValve Manifold Kit PartsNon-CirculatingKitsCirculating Kits56 332455F

Strona 53 - 332455F 53

PartsRef.No.Part No. DescriptionQty116N271MANIFOLD, for circulating kits2111450O-RING; chemically resistant24T581VALVE, for non-circulatingkits; inclu

Strona 54 - 54 332455F

PartsReference NumbersKit No.12345678 1012 131415 1618 1924T6661122 21 1 22 12 1 1 3 22 22 21511224T6671122 22 0 22 12 1 1 3 23 23 22510024T6681224 23

Strona 55 - 332455F 55

PartsHigh Pressure Circulating Valve Manifold Kit Part QuantitiesReference NumbersKit No.12345678 1012 1314151618 192224T677121 022 1135520100124T6782

Strona 56 - 56 332455F

ModelsIntrinsicallySafeKitsSee the module identification label for product part number, maximum air working pressure, and approvalinformation and certi

Strona 57 - 332455F 57

PartsColor Change Control Module KitsNon-IS Color Change Control Modules60 332455F

Strona 58 - 58 332455F

PartsRef.No.PartNo.DescriptionQty301 16P855 PANEL 1302 24T566BOARD, circuit1302a 123690FUSE; 125 mA1303 112324SCREW, machine, pan head;4–40 x 0.25 in.

Strona 59 - 332455F 59

PartsIS Color Change Control Modules62 332455F

Strona 60 - Color Change C

PartsRef.No.PartNo.DescriptionQty301 16U742 PANEL 1302 24T566BOARD, circuit1302a 123690FUSE; 125 mA1303 112324SCREW, machine, pan head;4–40 x 0.25 in.

Strona 61 - 332455F 61

PartsExpansion KitsNon-IS Expansion KitsThe followingkits are available to add color valves in a non-IS area. See Install an Expansion Kit, page 28 fo

Strona 62 - 62 332455F

PartsIS Expansion KitsThefollowingkitsareavailabletoaddcolorvalvesinanISarea. SeeInstall an Expansion Kit, page 28 forinstructions.Low Pressure Expans

Strona 63

DimensionsDimensionsFigure 25 Non-IS Control ModuleABCDEF11.30 in. (1478mm)7.67 in. (195mm)9.8 in. (249 mm) 5.70 in. (145mm)0.31 in. (8 mm) 5.80 in. (

Strona 64 - Expansion Kits

DimensionsNOTE: Total height of valve stack = H + K + (J xnumber of manifold blocks in your stack).Figure 27 ManifoldGHJKLMNPRSLow Pressure Valve Mani

Strona 65 - IS Expansion Kits

DimensionsFigure 28 Manifold Mounting BracketTUV3.84 in. (98mm)11.44 in. (291mm)0.312 in. (8mm) diameter68 332455F

Strona 66 - Dimensions

WeightsWeightsLow Pressure Non-Circulating Valve Manifold KitsKit No. lbgrams24T457 1.90 86324T458 2.82 127724T459 2.80 126924T460 3.71 168424T461 3.6

Strona 67 - 332455F 67

WarningsWarningsThe followingwarnings are for the setup, use, grounding, maintenance and repair of this equipment. Theexclamation point symbol alerts

Strona 68 - 68 332455F

WeightsHigh Pressure Non-Circulating Valve Manifold KitsKit No. lbgrams24T6477.7350324T648 11.5 521024T649 11.7 532924T650 15.5 703624T651 15.8 715424

Strona 69 - 332455F 69

WeightsNon-IS Color Change Control ModulesKit No. lbgrams24T557 9.7 438624T558 10.1 457624T559 10.5 476624T560 10.9 4956Non-IS Color Change Control Mo

Strona 70 - 70 332455F

NotesNotes72332455F

Strona 71

Technical DataTechnical DataColor Change Kits U.S.MetricMaximum fluid workingpressure:Low pressure kits 300 psi 2.1 MPa, 21 barHigh pressure kits1500 p

Strona 72

Graco Standard WarrantyGraco warrants all equipment referenced in this document which is manufactured by Graco and bearing itsname to be free from def

Strona 73 - Technical Data

WarningsWARNINGINTRINSIC SAFETYIntrinsically safe equipment that is installed improperly or connected to non-intrinsically safeequipment will create a

Strona 74 - Graco Standard Warranty

WarningsWARNINGPERSONAL PROTECTIVE EQUIPMENTWear appropriate protective equipment when in the work area to help prevent serious injury,including eye i

Komentarze do niniejszej Instrukcji

Brak uwag