11308687
Accessories
Shutoff valve 108458
Install upstream from the meter. Shuts off fluid supply
from the pump. 1/2–14 npt(f) both ends.
Thermal Relief Kit 235998
(1/2–14 npt(m) x 1/2–14 npt(f)
Install downstream from the pump.
Strainer Kit 239876
(includes strainer and o-ring)
Install the strainer before the meter or before the valve
on the meter/valve combination.
Install the o-ring after the strainer to hold the strainer in
place. See below.
7464A
strainer
o-ring
Technical Data
Flow range 0.5 to 5 gpm (1.9 to 19 lpm). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Maximum working pressure 500 psi (3.4 MPa, 34 bar). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Minimum working pressure 5 psi (34 kPa, 0.3 bar). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Weight 1.8 lb (0.82 kg). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Units of measurement Factory-set in quarts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Display shows quantity in 0.01 increments
up to 999.99 gallons, quarts, pints, or liters.
Totalizes in gallons or liters up to 99,999 units.
{
Accuracy +/– 0.5 percent. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
}
Repeatability +/– 0.15 percent. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Inlet and outlet 1/2 npt. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Meter can be installed with flow in either direction.
Operating temperature range –4_ F to 122_ F. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(–20_ C to 50_ C)
Storage temperature range –13_ F to 122_ F. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(–25_ C to 50_ C)
Wetted parts nickel, zinc, LCP, nitrile rubber. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
* Battery standard 9V alkaline. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Expected battery life in a typical shop environment 6 to 12 months. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
{
At 2.5 gpm (9.5 lpm), at 70_ F (21_ C), with 10-weight oil, and 1 gallon dispensed.
May require calibration; out-of-box accuracy is +/– 1.25 percent.
}
At 2.5 gpm (9.5 lpm), at 70_ F (21_ C), with 10-weight oil, and 1 gallon dispensed.
* Battery required to meet safety approvals:
DuracellR MN1604, Duracell PC1604, EvereadyR EN22, Eveready 522
DuracellR is a registered trademark of Duracell Inc.
EvereadyR is a registered trademark of Eveready Battery Co., Inc.